WEH Catalog 40 - Refrigerating & Air Conditioning
»
Overview
TESTING OF TUBE CONNECTIONS
Type
TW141
TW221
TW230
TW241
6.0 - 22.2 mm tube OD
9.5 - 24.4 mm tube ID
9.5 - 22.2 mm tube ID
6.0 - 22.2 mm tube OD
Sealing range
Max. allowable operating pressure PS
Vacuum up to 100 bar
3 bar
Vacuum up to 70 bar
Vacuum up to 70 bar
Seals
O-ring sealing
Special sealing
O-ring sealing
Special sealing
Nominal bore (DN)
3 to 5 mm
2 to 4 mm
2 to 5 mm
4 to 6 mm
EXAMPLES OF USE
TW111 | For filling and evacuating of industrial refrigerating and air conditioning systems
TW110 | For filling and evacuating of au tomotive air conditioning systems during production
TW141 | For testing of cooling circuits
ORDERING
Normally we need the following information when ordering: 1. Part no.
5. Temperature range
2. Pressure range
6. Space requirement (interference contours, clearance, etc.) 7. CAD drawing of customer test piece with tolerances
3. Medium / leak rate
4. Description of application
8. Test piece
For reasons of precaution, we‘d like to point out that a) regarding the delivery of each article acc. to the respective order confirmation - in particular concerning ECE / EC79 articles - WEH does not confirm the fulfilment of additional requirements of the concerned end customer, b) WEH is not subject to any external reporting obligation with regard to external change management (see page 44) and c) WEH does not confirm the replacement of the product in the form of a regular series delivery. Exclusions acc. to a) - c) can be agreed with the conclusion of a customer-specific project with corresponding special conditions.